fluxus rate probatorem conflandum
Melt Flow Rate Test Equipment,MFI Melting Flow Index Tester,MFI Testing Device ISO1133
Melt Flow Rate Test Equipment,MFI Melting Flow Index Tester,MFI Testing Device ISO1133
Discription:
Melt flow rate testing instrument can be used for ABS, polystyrene, polyethylene, polypropylene, polyamide, fiber resin, acrylate, POM, plastic fluorine, polycarbonate and other plastic materials, the melt flow rate (MFR) or the melt volume flow rate (MVR) to be determined.
Latin:
GB/T3682-2018,ISO1133-2011, ASTM D1238
Melt Flow Rate Test Equipment,MFI Melting Flow Index Tester,MFI Testing Device ISO1133
Product Character:
1.English LCD Touched Screen.
2.Hand automatic cutting material.
3.Double temperature control system, temperature control precision is more accurate, higher heating efficienc
4.Double imported sensors, more accurate temperature gradient from top to bottom, can be used independently, and improve the service life.
5. Cylinder for imports hartz alloying nitriding treatment, opening mould for carbon tungsten steel material, material reality.
6.Insulation barrels of sus304 stainless steel material for the whole, long-term high temperature does not rust.
7.Automatic calculation results, and print.
Test Methods:MFR Methods
Display Mode:English color touch screen display
Melt Flow Rate Test Equipment,MFI Melting Flow Index Tester,MFI Testing Device ISO1133
specification
model | LR-A001-A |
Barrel parameters | Inner hole 9.550±0.005mm |
Pistons parameters | Piston head: 9.474±0.005mm |
Outlet length | 8.000±0.025mm |
Paramters | Extrusion hole 1=2.095±0.005mm |
Temperature parameter | With intelligent temperature control instrument, with four pairs of significant temperature setting control, PID parameters can be automatically set, precision up to ± 0.1 degree centigrade |
temperatus range | Room Temperature~450degree centigrade |
Temperature fluctuatio, | ±0.2 |
Temperature uniformity | ± I ℃ |
Temperature display resolution | 0.1℃ |
display senatus | 0.1℃ |
Maximum comsuption | < 600W |
Time display resolution | 0.1s |
Weight parameters are as follows: | |
Weight accuracy | ± 0.5% |
basic configuratione
|
A 0.325kg |
B 1.2kg | |
C 2.16kg | |
D 3.8kg | |
E 5kg | |
F 10kg | |
G 12.5kg | |
H 21.6kg | |
Position detection | |
Loop distance from up and down | 30mm |
Control precision | ± 0.1mm |
Test flow control | |
Times of cutting the material | 0~10 times |
Material cutting interval | 0~999s(set reference Table 2) |
Control flow reaches the set temperature without volatility | |
Barrel temperature time | 15 mihi. |
Material be installed | 1 mihi. |
Material sample temperature recovery time | 4 mihi. |
When binder set |
1mihi |
Output mode | Micro-automatic print output |
Cut material methods | The hand automatic cut into one body |
test onus | Eight sets of weights |
imperium | AC220V±10% 50/60HZ |