-Testis universae Machina, Testis impulsum Machina-

sicine subrepsti tentationis machina

» sicine subrepsti tentationis machina

  • depictio producti
  • deformatio
  • High temperature furnace
  • structure

RC Series Mortuus Pondus Creep & Ruptura Testis Machina are designed and built for testing the creep properties and creep rupture strength on ferrous metal, metalli non ferrei eorumque stannum subditi ad certum temporis intervallum distrahentes constanti onere temperie. Disponitur secundum "calditate repunt caliditas" & ruptura vires GB/2039-1997" National Standard. interim, it conforms to ISO204/1997 International Standard and HB5151-96 Aviation Industrial Standard. It can offer liable test/inspection certificate for aviation Industry & other special materials property that should endure high temperature.

capacity: Model RC-30: 30KN,; Model RC-50: 50KN,; Model RC-100: 100KN,; Model RC-200: 200KN,

onus range: 2-100% habitum

onus accuracy: ≤±1.0%

Variation of indicating load value: ≤±1.0%

The eccentricity of the upper and lower chucks: ≤10%

Min dead weight load: 1N

Automatic level range: ±0.1mm

Lever ratio: 1:50 / 1:100

Lower tensile rod speed: 0-50mm / min

Lower tensile rod stroke: 0-150mm for RC-30 and RC-50; 0-200mm for RC-100 and RC-200

  • Gaugelength: 50mm (or 100mm);
  • deformatio: 5mm (or 10mm)
  • senatus: 0.001mm
  • Error: 0.002mm

High temperature furnace & Temperature-controller

  • Working Temp. range: 400℃~1200℃
  • Length of effective soaking zone: 150mm
  • Furnace pipe & electric furnace size:

Furnace pipe: φ90mm (Inner Dia.)×400mm (I.),

Furnace: φ300mm (outer Dia,)×420mm (I.);

Furnace life: ≥3000hours (Constant working time less than 1000℃)

  • Furnace Temperature accuracy (℃):

Test Temperature

Temperature fluctuatio,

Temperature gradient

≤600

± II

2

>600~900

± III

3

>900~1200

± IV

4

  • modum & Control temperature meter:digital display, sensibilitatem: 0.1℃;
  • Auto compensation error of cold end:≤0.5℃;
  • To be matched freely with thermocouple.
  • Moving speed of lower grip holder

This testing machine consists of main unit, heating furnace, temperature measuring system, and deformation measuring system. The main unit & heating furnace forms a complete set in applications. Temperature measuring system adopts group control & centralized administration. Deformation measuring system features as centralized checking, auto recording & random looking over history test data

forma inquisitionis (ASAP erimus ad vos redire)